  • Real-time detection using electrochemical microsensors
  • Integrated system - includes sensors and start-up kit
  • Measure up to 4 species in the same preparation
  • Wide dynamic range for detection
  • Measure nitric oxide, hydrogen peroxide, hydrogen sulfide, glucose, and oxygen
Description Details
Current measurement range from 300 fA to 10 µA (four ranges) permits wide dynamic range for detection * Wide bandwidth allows recording of fast events * Measure nitric oxide from < 0.3 nM to 100 µM * Measure hydrogen peroxide < 10 nM to 100 mM * Measure hydrogen sulfide * Measure glucose * Measure oxygen from 0.1% to 100% * Isolated architecture allows Lab-Trax interface to simultaneously measure free radical and independent analog data (i.e., ECG, BP, etc.) data on any channel

Real-time detection
Real-time detection and measurement of a variety of redox-reactive species is fast and easy using the electrochemical (amperometric) detection principle employed in the new TBR4100. This optically isolated four-channel free radical analyzer has ultra low noise and independently operated channels.

Measure multiple species
For use with WPI’s wide range of nitric oxide, hydrogen peroxide, hydrogen sulfide and oxygen sensors, the TBR4100 can measure four different species simultaneously in the same preparation. Simply plug a sensor into any one of the input channels on the front panel and select the current range. Poise voltage can be selected from a range of values tuned for optimal response from WPI sensors. An independent output for real-time monitoring of temperature is also included.

Data acquisition
The TBR4100 analyzer utilizes PC-based data acquisition via our Lab-Trax interface; data traces are displayed and recorded in real-time. The Data-Trax software comes pre-configured for single or multiple electrode recording; filters, gains, and smoothing are all set for optimal results. Data can be viewed making adjustments to smoothing and filter settings without affecting the original stored raw data. Electrode calibration from multiple concentration readings can be input into the software's Multipoint Calibration utility quickly provides a plot and slope calculation for electrode sensitivity determination. Alternately, the Lab-Trax T series data interface can be used for providing simultaneous acquisition of Free Radical data along with other physiological data (ECG, HR, BP, etc.) as each of the four input channels has its own independent input amplifier, filters, and 24-bit converter.

Turnkey systems
TBR4100-416 includes TBR4100 analyzer & power cord, Lab-Trax-4/16 data acquisition system & USB cable, 4 BNC cables, 3 electrode adapter cables, 1 temperature probe, 2 sensors of your choice, and sensor start-up kit(s), if applicable * TBR4100-424T includes TBR4100 analyzer & power cord, Lab-Trax-4/24T data acquisition system & USB cable, 4 BNC cables, 3 electrode adapter cables, 1 temperature probe, 2 sensors of your choice, and sensor start-up kit(s), if applicable
Specifications
Power 100 ~ 240 VAC, 50-60 Hz, <15 W
Operating Temperature (ambient) 0 - 50°C (32 - 122°F)
Operating Humidity (ambient) 15 – 70% RH non-condensing
Warm up Time <5 minutes
Dimensions 135 X 419 X 217 mm (5.25” X 16.5” X 8.16”)
Weight 1.35 kg (3 lb)
Display Functions 18 mm (0.7”) LCD readout, 4.5 digit Polarization Voltage (mV) Current input (nA, µA)
Controls Power (on/off) Current Input Range Polarization Voltage
Analog Output Range +/- 10 V (continuous)
Analog Output Impedance 10 kohm
Channel to Channel Isolation >10 Gohm
Channel to Output Isolation >10 Gohm
Power Supply to AC Line Isolation >100 Mohm
Analog Output Drift <10 pA/h
Temperature Input: Number of Channels 1
Temperature Input: Sensing Element Platinum RTD, 1000 Ohm
Temperature Input: Range 0-100°C
Temperature Input: Accuracy +/- 1°C
Temperature Input: Resolution 0.1°C
Temperature Input: Analog Output 31.25 mV/°C (continuous)
Amperometric Input: Number of Amperometric Channels 4
Amperometric Input: Signal Bandwidth 0-3 Hz
Amperometric Input: Polarization Voltage (selectable via rotary switch)
Amperometric Input: Polarization Voltage (selectable via rotary switch) Nitric Oxide 865 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Sulfide 150 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Peroxide 450 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Glucose 600 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Oxygen 700 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) ADJ (user adjustable) +/- 2500 mV
Polarization Voltage Accuracy +/- 5 mV
Polarization Voltage Display Resolution +/- 1mV
Current measurement Performance: Range +/- 10 Na, +/- 100 nA, +/- 1 µA, +/- 10 µA
Current measurement Performance: Analog Output 1 mV / 1 pA, 1 mV / 10pA, 1 mV / 100pA, 1 mV / 1µA
Current measurement Performance: Noise @ 3Hz * < 1 pA, < 7 pA, < 70 pA, < 700 pA
Current measurement Performance: Noise @ 0.3 Hz * < 0.3 pA, < 3 pA, < 30 pA, < 300 pA
Notes: *Instrument performance is measured as the (max-min) over 20 seconds period with open input. Typical values are given at 3 Hz and 0.3 Hz bandwidth.
Typical sensor performance with TBR4100: ISO-NOPF100 noise 0.2 nM NO (<2 pA)**
Notes: **Sensor noise is measured as the (max-min) over a 20 seconds period with the sensor immersed in 0.1 M CuCl2 solution.
Manuals and Resources Instruction Manual
TBR4100_IM_20081027.pdf
DataTrax2_066_mac_Installer.dmg.zip
datatrax2_066_mac_update.zip
datatrax2_Installer_PC_2.079.zip
DataTrax2_Update_PC_2.079.zip
References Have you seen a reference to this product in a published paper? If so, email your contact information and the citation and we will send you a free gift!
Ordering Information To place an order for this product, please contact the appropriate WPI office or distributor.

Customers can order direct from our China office:
WPI China
Address: Rm.20A, No.8 Dong Fang Rd, Liang Feng Building, Lu Jia Zui Financial District, Shanghai PRC
Phone:+86 21 68885517
Fax:+86 21 68885537
Code:200120
Accessories
Application Notes Application Notes No Application Notes available for this product at this time.
©Copyright 2008 World Precision Instruments, Inc. All Rights Reserved.